CSSD Autoclave sterilization Machine for Garments, Surgical Instruments
CSSD Autoclave sterilization Machine for Garments, Surgical Instruments
CSSD Autoclave sterilization Machine for Garments, Surgical Instruments
CSSD Autoclave sterilization Machine for Garments, Surgical Instruments
Model
MDD-0.25,0.36,0.6,0.8,1.0,1.2

Item specifics

Loading Capacity
250, 360, 600, 800,1000, 1200 LITER
Customized
Available
Application
Garments, Surgical Instruments, Etc
Door
Pass-through Double Doors

Review

Description

                               CSSD AUTOCLAVE STERILIZATION MACHINE AIKS-MDD SERIES

MDD Series Steam Sterilizers are used for garments & surgical Instruments sterilization in CSSD healthcare industry.

                                 AIKSMED provides wide range of dimensions for options,

                              including 11 kinds of volumes from 250 liters to 1200 liters.

                          
Application
wholesale saturated steam autoclave sterilization machine for CSSD in hospitals.
CSSD autoclave sterilization

CSSD autoclave sterilization

AKS-ASMD Series 

Model

Chamber Size

Chamber Volume

AKS-MDD-0.25
500*500*1000
250L
AKS-MDD-0.36
600*600*1000
360L

AKS-MDD-0.6

610*910*1200

600L

AKS-MDD-0.8

610*910*1500

800L

AKS-MDD-1.0

610*910*1800

1000L

AKS-MDD-1.2

680*1180*1500

1200L

★★★Features:
autoclave sterilization machine


  Main components of the sterilizer: sterilization chamber, sealing door, pipeline system, control system, loading&transfer system;

 Design pressure up to 0.3MPa/3bar.

Autoclave vessel is made of AISI316L/304.

Housing, support frame, chamber made of corrosion-resistant stainless steel material.

  Safety valves for chamber, with over-pressure protection.

   Door interlock security system.

  Door lock with durable, heat and pressure-resistant seal/gasket.

   Touch screen control.

   Access code to prevent uncontrolled software changes

   Three-level authority management.

   Up to 100 sterilization cycles.

   Portable PT-100 temperature sensor (class A).

   Display of sterilization temperature, time, F0 value in real time.

   Validation port to test thermal distribution.

   Network and USB ports for data transfer.
 
   Emergency stop button to stop autoclave cycles.

   Alarm information in form of code and full message.

Garments steam sterilizer chamber
Design
■ Advanced structure of chamber combined with jacket for faster heating-up and cooling, due to more contact areas.

■ Totally 4 chamber diameter are available

autoclave sterilization cycle
Operation

Pulse Vacuum Sterilizer Air Filter
Air inlet & Extract Filtration

Pulse Vacuum Sterilizer Equipment Drainage
Drainage Cooling & Security System